被按摩的人妻中文字幕_丰满熟妇乱子伦_青青色无码视频在线观看_欧美猛少妇色XXXXX猛叫_97人视频国产在线观看

網(wǎng)站導(dǎo)航
網(wǎng)站首頁(yè)  ◇  產(chǎn)品展示    ◇  通用色譜柱 ◇   GC-PLOT柱 > Rt®-Alumina BOND/KCl Columns(熔融石英plot柱)

Rt®-Alumina BOND/KCl Columns(熔融石英plot柱)

更新時(shí)間:  2017-07-09

產(chǎn)品型號(hào):  

產(chǎn)品報(bào)價(jià):  

所  在  地:  北京市朝陽(yáng)區(qū)望京西園222號(hào)星源國(guó)際D座1503室

產(chǎn)品特點(diǎn):  The Rt?-Alumina BOND column is stable up to 200 °C. If water is adsorbed on the column, it can be regenerated by conditioning at 200 °C. Full efficiency and selectivity will be restored.

(聯(lián)系我們,請(qǐng)說(shuō)明是在 北京明尼克分析儀器設(shè)備中心 上看到的信息,謝謝?。?/div>

產(chǎn)品概述

Rt®-Alumina BOND/KCl Columns (fused silica PLOT)

(KCl deactivation)

Guaranteed Reproducibility
Each Rt
®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene.
With our new technology, both Na
2SO4 and KCl are available with the Rt®-Alumina BOND columns.

Similar Phase(s):

GC-Alumina KCl, CP-Al2O3/KCl

catalog #

length

id

df

units

 

19761

30m

0.32mm

5μm

ea.

19762

50m

0.32mm

5μm

ea.

19759

30m

0.53mm

10μm

ea.

19760

50m

0.53mm

10μm

ea.

Showing 1 to 4 of 4 entries

 

1. Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures. 2. Reactivity of aluminum oxide stationary phase is minimized so that column response for polar unsaturates, such as dienes, is optimized. Column sensitivity or response ensures a linear and quantitative chromatographic analysis for these compounds. 3. Strong bonding prevents particle generation. The column can be used in valve switching operations, without release of particles that can harm the injection and detection systems. 4. The Rt®-Alumina BOND column is stable up to 200 °C. If water is adsorbed on the column, it can be regenerated by conditioning at 200 °C. Full efficiency and selectivity will be restored. 5. High capacity and loadability give exceptionally symmetric peaks; ideal for volatile hydrocarbon separations at percent levels, as well as impurity analyses at ppm concentrations.

Guaranteed Reproducibility Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene. Extensive testing assures reproducible retention times and predictable flow behavior column-to-column.

*       Acetylene elutes before C4 hydrocarbons (impurities in butane/isobutane).

*       Methyl acetylene (impurity in 1,3-butadiene) elutes before 1,3-butadiene.

 

 

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
北京明尼克分析儀器設(shè)備中心

北京明尼克分析儀器設(shè)備中心

聯(lián)系人:薛海玲  電話:010-84723211  郵箱:xuehail@163.com  總部地址:北京市朝陽(yáng)區(qū)望京西園222號(hào)星源國(guó)際D座1503室

研發(fā)中心:北京市平谷區(qū)中關(guān)村科技園區(qū)興谷A區(qū)平和街39號(hào)院(聯(lián)東U谷)22號(hào)樓C區(qū)

版權(quán)所有 © 2024 北京明尼克分析儀器設(shè)備中心  總流量:985807  備案號(hào):京ICP備10037012號(hào)-2

管理登陸  網(wǎng)站地圖  技術(shù)支持:化工儀器網(wǎng)