您好,歡迎來(lái)到北京明尼克分析儀器設(shè)備中心網(wǎng)站!
更新時(shí)間: 2017-07-09
產(chǎn)品型號(hào):
所 在 地: 北京市朝陽(yáng)區(qū)望京西園222號(hào)星源國(guó)際D座1503室
產(chǎn)品特點(diǎn): The Rt?-Alumina BOND column is stable up to 200 °C. If water is adsorbed on the column, it can be regenerated by conditioning at 200 °C. Full efficiency and selectivity will be restored.
共創(chuàng)共贏
產(chǎn)品概述
Rt®-Alumina BOND/KCl Columns (fused silica PLOT)
(KCl deactivation)
Guaranteed Reproducibility
Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene.
With our new technology, both Na2SO4 and KCl are available with the Rt®-Alumina BOND columns.
Similar Phase(s):
GC-Alumina KCl, CP-Al2O3/KCl
catalog # | length | id | df | units | |
19761 | | | 5μm | ea. | |
19762 | | | 5μm | ea. | |
19759 | | | 10μm | ea. | |
19760 | | | 10μm | ea. | |
Showing 1 to 4 of 4 entries
1. Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures. 2. Reactivity of aluminum oxide stationary phase is minimized so that column response for polar unsaturates, such as dienes, is optimized. Column sensitivity or response ensures a linear and quantitative chromatographic analysis for these compounds. 3. Strong bonding prevents particle generation. The column can be used in valve switching operations, without release of particles that can harm the injection and detection systems. 4. The Rt®-Alumina BOND column is stable up to
Guaranteed Reproducibility Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene. Extensive testing assures reproducible retention times and predictable flow behavior column-to-column.
Acetylene elutes before C4 hydrocarbons (impurities in butane/isobutane).
Methyl acetylene (impurity in 1,3-butadiene) elutes before 1,3-butadiene.
北京明尼克分析儀器設(shè)備中心
聯(lián)系人:薛海玲 電話:010-84723211 郵箱:xuehail@163.com 總部地址:北京市朝陽(yáng)區(qū)望京西園222號(hào)星源國(guó)際D座1503室
研發(fā)中心:北京市平谷區(qū)中關(guān)村科技園區(qū)興谷A區(qū)平和街39號(hào)院(聯(lián)東U谷)22號(hào)樓C區(qū)
版權(quán)所有 © 2024 北京明尼克分析儀器設(shè)備中心 總流量:985807 備案號(hào):京ICP備10037012號(hào)-2
管理登陸 網(wǎng)站地圖 技術(shù)支持:化工儀器網(wǎng)